Candida Antibodies, IgM, ELISA

CPT: 86628
Updated on 12/4/2024
Print Share

Special Instructions

This assay currently is not available in New York state.

This assay is currently not available in New York state.

This assay currently is not available in New York state.


Expected Turnaround Time

1 - 5 days


Related Documents


Specimen Requirements


Specimen

Serum


Volume

1 mL


Minimum Volume

0.25 mL


Container

Red-top tube or gel-barrier tube


Storage Instructions

Room temperature


Stability Requirements

TemperaturePeriod
Room temperature14 days
Refrigerated14 days
Frozen14 days
Freeze/thaw cyclesStable x4

Causes for Rejection

Microbially-contaminated specimen; heat-treated specimen; specimens containing particulate matter; gross hemolysis; lipemia or icterus


Test Details


Use

Detection of IgM antibodies to Candida albicans


Limitations

Results for this test are for research purposes only by the assay's manufacturer. The performance characteristics of this product have not been established. Results should not be used as a diagnostic procedure without confirmation of the diagnosis by another medically established diagnostic product or procedure.

A positive test does not necessarily indicate infection since antibodies to Candida species can be detected in uninfected individuals because of their exposure to commensal yeasts. This assay is unable to differentiate antibodies formed during mucosal colonization from those produced during deep infection. Consequentially, antibodies are found in many hospitalized patients who have no obvious Candida infection. A negative result does not rule out the possibility of deep-seated candidiasis in immunocompromised patients.


Methodology

Enzyme-linked immunosorbent assay (ELISA)


Reference Interval

Negative


LOINC® Map

For Providers

Please login to order a test

Order a Test

© 2021 Laboratory Corporation of America® Holdings and Lexi-Comp Inc. All Rights Reserved.

CPT Statement/Profile Statement

The LOINC® codes are copyright © 1994-2021, Regenstrief Institute, Inc. and the Logical Observation Identifiers Names and Codes (LOINC) Committee. Permission is granted in perpetuity, without payment of license fees or royalties, to use, copy, or distribute the LOINC® codes for any commercial or non-commercial purpose, subject to the terms under the license agreement found at https://loinc.org/license/. Additional information regarding LOINC® codes can be found at LOINC.org, including the LOINC Manual, which can be downloaded at LOINC.org/downloads/files/LOINCManual.pdf