所在地を検索
営業時間、予約なし診療およびご予約。Unable to load global navigation.
所在地を検索
営業時間、予約なし診療およびご予約。D-dimer; fibrinogen; fibrinogen degradation products (FDP), plasma; platelet count; partial thromboplastin time (PTT); prothrombin time (PT)
If the patient's hematocrit exceeds 55%, the volume of citrate in the collection tube must be adjusted. Refer to Coagulation Collection Procedures for directions.
2 - 3 days
Turnaround time is defined as the usual number of days from the date of pickup of a specimen for testing to when the result is released to the ordering provider. In some cases, additional time should be allowed for additional confirmatory or additional reflex tests. Testing schedules may vary.
For more information, please view the literature below.
Procedures for Hemostasis and Thrombosis: A Clinical Test Compendium
Whole blood and plasma, frozen
5 mL EDTA whole blood, one citrated whole blood tube, and two transfer tubes with 1 mL frozen sodium citrate plasma in each tube
Lavender-top (EDTA) tube and blue-top (sodium citrate) tubes
Blood should be collected in a blue-top tube containing 3.2% buffered sodium citrate.1 Evacuated collection tubes must be filled to completion to ensure a proper blood to anticoagulant ratio.2,3 The sample should be mixed immediately by gentle inversion at least six times to ensure adequate mixing of the anticoagulant with the blood. A discard tube is not required prior to collection of coagulation samples.4,5 When noncitrate tubes are collected for other tests, collect sterile and nonadditive (red-top) tubes prior to citrate (blue-top) tubes. Any tube containing an alternate anticoagulant should be collected after the blue-top tube. Gel-barrier tubes and serum tubes with clot initiators should also be collected after the citrate tubes. Centrifuge and carefully remove the plasma using a plastic transfer pipette, being careful not to disturb the cells. Transfer the plasma into a Labcorp PP transpak frozen purple tube with screw cap (Labcorp No. 49482). Freeze immediately and maintain frozen until tested.
Please print and use the Volume Guide for Coagulation Testing to ensure proper draw volume.
Maintain whole blood at room temperature. Freeze plasma.
None
Severe hemolysis; improper labeling; clotted specimen; specimen diluted with IV fluids; samples thawed in transit; improper sample type; sample out of stability
Identify the presence and follow the course of disseminated intravascular coagulation (DIC)
See individual tests.
Order Code | Order Code Name | Order Loinc | Result Code | Result Code Name | UofM | Result LOINC |
---|---|---|---|---|---|---|
116012 | DIC Profile | 001610 | Fibrinogen Activity | mg/dL | 3255-7 | |
116012 | DIC Profile | 115402 | FDP, Plasma | ug/mL | 30226-5 | |
116012 | DIC Profile | 115107 | INR | 6301-6 | ||
116012 | DIC Profile | 015289 | Prothrombin Time | sec | 5902-2 | |
116012 | DIC Profile | 015116 | aPTT | sec | 14979-9 | |
116012 | DIC Profile | 015172 | Platelets | x10E3/uL | 777-3 | |
116012 | DIC Profile | 115206 | D-Dimer | mg/L FEU | 48065-7 |
Reflex Table for INR | ||||||
---|---|---|---|---|---|---|
Order Code | Order Name | Result Code | Result Name | UofM | Result LOINC | |
Reflex 1 | 115109 | INR (Thromborel-S) | 115109 | INR (Thromborel-S) | 6301-6 |
Reflex Table for Prothrombin Time | ||||||
---|---|---|---|---|---|---|
Order Code | Order Name | Result Code | Result Name | UofM | Result LOINC | |
Reflex 1 | 015290 | PT (Thromborel-S) | 015290 | PT (Thromborel-S) | sec | 5902-2 |
© 2021 Laboratory Corporation of America® Holdings and Lexi-Comp Inc. All Rights Reserved.
CPT Statement/Profile Statement
The LOINC® codes are copyright © 1994-2021, Regenstrief Institute, Inc. and the Logical Observation Identifiers Names and Codes (LOINC) Committee. Permission is granted in perpetuity, without payment of license fees or royalties, to use, copy, or distribute the LOINC® codes for any commercial or non-commercial purpose, subject to the terms under the license agreement found at https://loinc.org/license/. Additional information regarding LOINC® codes can be found at LOINC.org, including the LOINC Manual, which can be downloaded at LOINC.org/downloads/files/LOINCManual.pdf